Master Battery Disconnect Kit
Master Battery Disconnect Kit
This kit allows for manual disconnect of high current battery lines. Ideal for isolating battery banks by interrupting output circuits on your battery bank. For use when putting a system with DC charging input into medium-long term storage, or for O&M of the battery bank. This switch is typically used between a battery bank and a post or fuse that all the positive connections attach to.
We offer kits for systems with 2000VA or 3000VA inverters.
Please note, the 5000VA 12V inverters would need a more heavy-duty switch.
Specifications (2000VA/3000VA)
Continuous Rating: 350A/300A
Intermittent Rating: 600A (5 min)/500A
Maximum Voltage: 48Vdc/48Vdc
Dimensions: 3 7/8"H x 3 7/8"W x 3"D / 2 7/8"H x 2 7/8"W x 3 1/4"D
Wiring Diagram (3000VA)
Wiring Diagram (2000VA)
What you get:
96-BATTDISC3K
1x SWITCH-BS9003E Switch-BS 9003E On/Off
4x FSTSCW-102Z Screw-#10x2" PHP SMS Z
2x LUG-4/0-RING-3/8 4/0 Lug-3/8" Ring
3” HS-RED-HD-3/4 Heat Shrink 3/4" Red HD (1.5" pieces)
96-BATTDISC2K
1x SWITCH-MINI Switch-Mini On/Off
4x FSTSCW-10x2.75SS Screw-#10 X 2 3/4" PHP Tapping SS
2x LUG-2/0-RING-3/8 2/0 Lug-3/8" Ring
3” HS-RED-HD-3/4 Heat Shrink 3/4" Red HD (1.5" pieces)
You may also be interested in:
Used to clean up and mark positive/negative cable ends.
Recommended Heat Shrink Diameter for given Wire/Lug Gauge:
3/4" HD: 1/0, 2/0, 3/0, 4/0
1/2" HD: 2GA, 4GA,
1/2" DW: 6GA, 8GA
1/4" DW: 10GA
1/8" DW: 18GA
Typically used between the battery bank and a 2000W or larger inverter
Sold by the foot
For helpful advice on the differences between Parallel & Series connection and which might be best for you and your project, please see our wiki article here.
Cable, Lugs, and Heat Shrink needed to connect two batteries in parallel or series, depending on kit choice. These kits are ideal for 12V batteries.
AM Solar Part Number: 96-BATTDISC3K, 96-BATTDISC2K